Cummins brand power generation systems are the result of
integrated design and manufacturing intended to satisfy your requirements for rated
performance and reliable and efficient operation. For either standby or prime power,
Cummins produces a full line of diesel and spark-ignited generator sets, transfer switches,
paralleling switchgear, smart controls, sound attenuated housings, and installation
accessories. All products are designed and manufactured to work as a total,
integrated system. These power systems are backed by a worldwide network of
distributors and service branches plus a comprehensive warranty program. All systems
are subjected to prototype testing simulating rigorous real-world environments and meet
Cummins Total Quality System requirements. Cummins' manufacturing processes are ISO
9001 registered.
Extreme weather, construction activities, and countless other
unforeseen power complications can suddenly interrupt the electrical service you depend on
to continue your operations and activities. You can have complete peace of mind,
knowing that during a power outage your Cummins Standby System will activate to
provide the power necessary to run vital systems.
Fully automatic, the system detects an interruption of electrical
service and engages to power your essential systems. When utility power is restored,
the standby system shuts down, automatically resetting itself. The entire power
transfer cycle is fully automatic -- it is not necessary to be present for this system to
work!
Cummins Diesel Generator Sets
Cummins series water-cooled diesel-fueled
generator sets offer the traditional rugged durability and reliability in applications as
diverse as standby power for nursing homes or wireless services and prime power for small,
unattended remote stations or large applications. User-friendly operation and maintenance features
include:
* Weather-protective housings and coolant heaters to shield the genset
from extreme ambient conditions.
* Space-saving options, such as in-skid fuel tanks
* Mulit-level controls for automatic, local, or remote start
capabilities
* Complete options and accessories
If your requirements differ from those described here, click to request a custom quote.
Cummins Features
Compare these features with those offered on competitor's models.
Only more about the Cummins brand Cummins
* Single-source design, manufacturing and testing of all set
components and
accessories by Corporation.
* Most accept 100% of nameplate kW rating in one step, in compliance
with
NFPA 110, Paragraph 5-13.2.6.
* Shunt exitation system provides quick recovery from transient
speed dips.
* Designed with a complete line of factory options and accessories
for standby
and mobile power.
* Water-cooled diesel engine is mechanically or
electronically
governed and
has direct injection combustion.
* Most have brushless, rotating field YD AC alternator
that provides broad
range
reconnectible output. Single phase 4-lead alternator is
standard with 12-lead
optional.
* Control Panel: vibration isolated start/stop control with
various shutdowns.
* Electronic voltage regulator provides precise
regulation,
underfrequency compensation, and fast recovery from transient speed
dips.
* High ambient radiator cooling system.
* Skid base provides integral vibration isolation and supports the
alternator and engine.
Battery rack and cooling system mount to the skid base. Skid
bases are standard
on water-cooled models.
Standard Bill of Material
100DGDB Cummins Genset-Diesel,60Hz,100kW or 417 amps @ 240v. At the heart of the set
is Cummins Heavy Duty, Turbocharged Diesel Engine Model: 6BT5.9-G6.
A331-2 Duty Rating-Standby Power
L090-2 LISTING-UL2200
L097-2 Emissions-Tier1 levels
F182-2 Weather Protective Enclosure with internally mounted critical muffler.
Durable
E-Coat Green paint finish is standard. Dba level @ 23 feet = 84dba. Sound
Attenuated Enclosures available. See
options below.
R104-2 Voltage-120/240, Single Phase
B273-2 Alternator-60hz, 4 Lead, Single Phase, 125c
H643-2 SET CONTROL-PCC 2100 - Sophisticated, yet user friendly microprocessor control
that stores tons of information on the genset's performance.
B240-2 Exciter/Regulator-Torque Match
A356-2 Engine Governor-Mechanical, 5% Droop
H536-2 Display Language-English
KM65-2 CircuitBreakerMtg-Single Brkr,LeftOfGenEnd
KB26-2 Circuit Breaker-400a,2pole,240v,Thermo-Magnetic,Ul
F179-2 Skidbase-Housing Ready
E082-2 Engine Cooling-Radiator, 50c Ambient
H389-2 Shutdown-Low Coolant Level - Protects the engine from running with low coolant
which could cause damage.
E089-2 Extension-Engine Coolant Drain - Makes for quicker, easier maintenance intervals.
H036-2 Coolant Heater-120 Volt Ac, Single Phase - AC Heater that maintains a warm
temperature on the engine block to protect against wear and tear brought on by
cold weather starts.
L028-2 Genset Warranty-1 Year Base - Covers travel time, mileage, parts and labor for
period of 1 year following start-up services.
A322-2 Packing-Skid, Poly Bag
F065-2 Rack-Battery
H268-2 Extension-Oil Drain- Makes for quicker, easier maintenance intervals.
Options (order using drop down menus below)
· Upgrade to Stage 1 Sound Attenuated Enclosure. Decreases dba level from 84.4 to
76.6 dba.
· Upgrade to Stage 2 Sound Attenuated Enclosure. Decreases dba level from 84.4 to
69.6.
· Upgrade to 12 lead, full single phase output alternator, 105C temp rise - Largest
alternator end available from Cummins with greatest amount of motor starting kva with
least amount of harmonics distortion from no load to full load.
· Upgrade to 12 lead, full single phase output alternator, 125C temp rise - Same as
alternator above except @ 125C temp rise. The 105C is of the highest quality, but this
is superior to the quoted 4 lead alternator. 12 lead alternators can be reconnected to
any 3 phase voltage.
· 500 amp Circuit Breaker to replace the 400 amp breaker: The 100kw will deliver
521 amps
@ 240v and 0.8 pf. To maximize KW, you'll want to use the 500 amp breaker, otherwise
the set will never have the opportunity to max out due to the circuit breaker tripping.
· Electronic Governor- To replace the mechanical governor. Maintains the tightest
frequency and voltage regulation from no load to full load. +/- ½ %.
· 173 gallon, dual wall, sub base fuel tank with low fuel level switch and rupture basin
alarm. Genset mounted atop the tank and plumbed.
· DAY TANK- If the job calls to interface with a large primary tank, we can use the 70
gallon sub base tank and add an extra pump and float valve to make the sub base tank
act as a day tank.
· 5 Year Comprehensive Warranty on Genset. Extends the 1 year warranty through 5 full
years. Following the 1st year, the coolant heater is not covered.