Standby Generator Set
Briggs & Stratton® Home Standby
20,000W on LP, 18000W on NG
(see below for choice of transfer switches)

 

Protect your home and family from power outages with Briggs & Stratton 16-20kW home generator systems.  Perfect for medium-to-large homes, we provide you with reliable and flexible options to meet your home's power needs.

Many  Features - including some new ones

Flexible Placement - Tested against tough National Fire Protection Agency standards, these Briggs & Stratton 16kW and 20kW standby generators with metal enclosures can now be placed as close as 18" from the home providing more placement options in your yard.  Perfect for tight lot lines.

Reliable Engine Power - Powered by commercial-grade Vanguard engines that are design-engineered to dependably take on the most demanding jobs.

Power Solution Options - Choose between an Essential Power Plus! system that powers a select number of circuits and 2 air conditioners OR a Managed Whole House Power system that powers all of your household appliances and 2 air conditioners using the Load Control Center (LCCM).

Durable Enclosure - Rust resistant, Galvanneal steel enclosure is made from steel with a special coat of galvanized zinc to prevent rust.  Results in years of protection against chips and abrasions.

Electronic Governor - closely controls speed and output frequency for sensitive loads.

Quick Response - Automatically powers your home in seconds after sensing a power outage.

Long Warranty Standard - 4 Year Limited Parts and Labor Warranty.

Computer Friendly Power - Advanced alternator technology provides safe and stable power for computers and other sensitive electronics.


Specifications


Generator

Engine Make Premium OHV Briggs & Stratton Vanguard V-Twin
Engine Type 4-cycle, air cooled, with full pressure lubrication
Engine Displacement 993cc
AC Output Voltage 120/240VAC, 1 phase
AC Output Frequency 60Hz
AC Output Power - running/surge 20,000 Watts on LP
18,000 Watts on NG
AC Output Current - running 83.3 Amps on LP
75.0 Amps on NG
Alternator brush low-maintenance alternator
Control System - automatic remote starting
- oil high temperature
- low oil pressure
- overcrank fail to start
- overspeed
- transfer switch fault
- low AC voltage
- low AC frequency
- low battery voltage
- running time meter
- AC circuit breaker
- DC control fuse
Remote Indications - Remote LED panel optional
Cold weather options (thermostatically controlled) - oil warmers
- battery warmer
Fuel Consumption - LP Vapor
(11-14 in.W.C. pressure at full load req'd)
2.31 gal/h at half load, 3.75 gal/h at full load
Fuel Consumption - natural gas
(5-7 in.W.C. pressure at full load req'd)
187 cfh at half load, 280 cfh at full load
Dimensions L x W x H 48" x 34" x 31"
Weight 500 lbs.
Warranty 4 years consumer, no warranty for commercial or industrial use


Automatic Transfer Switches

Model 71055 71045 71038 71046
Circuits 1
(whole house)
1
(whole house)
1
(whole house)
1
(whole house)
Maximum Amps 100 100 200 200
Service Entrance Rated (with disconnect) no yes no yes
Voltage 120/240VAC 120/240VAC 120/240VAC 120/240VAC
Air Conditioning Control Module (ACCM)
normally closed contacts for controlling A/C units via thermostat
2 2 2 2
Switch type mechanically held mechanically held mechanically held mechanically held
Enclosure NEMA 3R
indoor or outdoor
NEMA 3R
indoor or outdoor
NEMA 3R
indoor or outdoor
NEMA 3R
indoor or outdoor
Dimensions D x W x H 6" x 12" x 16" 6" x 14" x 22" 7" x 16" x 22" 7" x 16" x 30"
Weight 24 lbs. 37 lbs. 38 lbs. 64 lbs.

 

Automatic Transfer Switches

Fully Automatic
All of our switches monitor utility and generator voltages and will automatically connect to the appropriate source of power.  The 100 amp and 200 amp switches are capable of "whole house" power transfer in residential and small business applications.  For whole house applications the switch amp rating must equal or exceed the utility service rating.  If feeding a sub-panel the switch must equal or exceed the sub-panel rating.

Safety Features
All switch models are solenoid-operated from utility or generator inputs and contain electrical interlock switches to eliminate the possibility of dangerous back feed to utility during an outage.  Switches are listed to UL Standard 1008.

 

.

 

Are YOU ready for the next power outage?

 1 Videos
 2 Outage Archives
 3 Utility Industry
 4 Why You Need Backup
 5 Personal Stories
 6 NoOutage Configurations
 7 Safety
 8 Sizing for Your Needs
 9 Voltage Drop Calculator
10 Test Reports
11 Placing Order
12 Equipment Leasing
13 Books & Videos  
14 Financing
15 Frequently Asked
16 Future Technologies
17 Electricity Glossary
18 Help with Plug Types
19 Who We Are
20 Why Buy Here
21 Our Customers
22 Pick a Contractor
23 Privacy Promise
24 Safe Shopping Guarantee
25 Terms & Conditions
26 What's New
27 Contacting Us
28 Parts Lookup
29 Parts & Service
30 Made in USA
31 Links

We welcome your feedback or questions.  Click here to contact us.
See our Terms & Conditions before using information or ordering from this web site.
Copyright © 1999-2025 NoOutage.com LLC. A Virginia LLC. All rights reserved.