Cummins brand power generation systems are the result of
integrated design and manufacturing intended to satisfy your requirements for rated
performance and reliable and efficient operation. For either standby or prime power,
Extreme weather, construction activities, and countless other
unforeseen power complications can suddenly interrupt the electrical service you depend on
to continue your operations and activities. You can have complete peace of mind,
knowing that during a power outage your Cummins Standby System will activate to
provide the power necessary to run vital systems.
Fully automatic, the system detects an interruption of electrical
service and engages to power your essential systems. When utility power is restored,
the standby system shuts down, automatically resetting itself. The entire power
transfer cycle is fully automatic -- it is not necessary to be present for this system to
work!
Cummins Diesel Generator Sets
Cummins series water-cooled diesel-fueled
generator sets offer the traditional rugged durability and reliability in applications as
diverse as standby power for nursing homes or wireless services and prime power for small,
unattended remote stations or large applications. User-friendly operation and maintenance features
include:
* Weather-protective housings and coolant heaters to shield the genset
from extreme ambient conditions.
* Space-saving options, such as in-skid fuel tanks
* Mulit-level controls for automatic, local, or remote start
capabilities
* Complete options and accessories
If your requirements differ from those described here, click to request a custom quote.
Cummins Features
Compare these features with those offered on competitor's models.
Only more about the Cummins brand Cummins
* Single-source design, manufacturing and testing of all set
components and
accessories by Corporation.
* Most accept 100% of nameplate kW rating in one step, in compliance
with
NFPA 110, Paragraph 5-13.2.6.
* Shunt exitation system provides quick recovery from transient
speed dips.
* Designed with a complete line of factory options and accessories
for standby
and mobile power.
* Water-cooled diesel engine is mechanically or
electronically
governed and
has direct injection combustion.
* Most have brushless, rotating field YD AC alternator
that provides broad
range
reconnectible output. Single phase 4-lead alternator is
standard with 12-lead
optional.
* Control Panel: vibration isolated start/stop control with
various shutdowns.
* Electronic voltage regulator provides precise
regulation,
underfrequency compensation, and fast recovery from transient speed
dips.
* High ambient radiator cooling system.
* Skid base provides integral vibration isolation and supports the
alternator and engine.
Battery rack and cooling system mount to the skid base. Skid
bases are standard
on water-cooled models.
Standard Bill of Material
40DGHD Cummins Genset-Diesel,60Hz,40kW, 40,000 watts. Surge KW = 53kw. At the heart of
Genset is Cummins Rugged, heavy duty, Turbo charged "B" series diesel engine.
A331-2 Duty Rating-Standby Power
L090-2 LISTING-UL2200
L097-2 Emissions-Tier1 levels
F182-2 Weather Protective Enclosure with Critical Muffler mounted inside enclosure to
decrease dba level and protect muffler from the elements. Dba level @ 23 feet
= 78.8 dba. See notes below for adders for more quiet enclosures.
R104-2 Voltage-120/240, Single Phase
B273-2 Alternator-60hz, 4 Lead, Single Phase, 125c
H643-2 SET CONTROL-PCC 2100 - Microprocessor Control, digital display that stores tons
of information on the genset.
B240-2 Exciter/Regulator-Torque Match
A356-2 Engine Governor-Mechanical, 5% Droop
H536-2 Display Language-English
KM65-2 CircuitBreakerMtg-Single Brkr,LeftOfGenEnd
KB21-2 Circuit Breaker-200a,2pole,240v,Thermo-Magnetic,Ul
F179-2 Skidbase-Housing Ready
E082-2 Engine Cooling-Radiator, 40c Ambient
E089-2 Extension-Engine Coolant Drain - Makes for quicker, easier maintenance intervals.
H036-2 Coolant Heater-120 Volt Ac, Single Phase - Maintains warm temperature on the
engine block and protects against wear and tear caused by cold weather starts.
L028-2 Genset Warranty-1 Year Base - Covers travel time, mileage, parts and labor.
A322-2 Packing-Skid, Poly Bag
F065-2 Rack-Battery
H268-2 Extension-Oil Drain - Makes for quicker, easier maintenance intervals with this
rubber tube that extends from the oil drain.
Options (order using drop down menus below)
· Upgrade to Stage One Sound Attenuated Enclosure to decrease dba level to
71.1 @ 23 feet.
· Upgrade to Stage Two Sound Attenuated Enclosure to decrease dba level to
63.9 (extremely quiet).
· Low coolant shutdown: Will shutdown engine should the radiator's coolant run low.
· 12 lead, full 1 phase alternator, 105C temp rise: Provides greater motor starting kva
with the least amount of harmonics distortion from no load to full load. Can also be
reconnected to any 3 phase voltage. Should the customer ever want to relocate, the
resell value is greater w/ the 12 lead alternator.
· Electronic Governor - To maintain the tightest control on voltage and frequency
regulation.
· uel Tank-Dual Wall Subbase. - 145 gallon capacity. @ ¼ load = 132 hours, @ ½ load =
80 hours, @ ¾ load = 61 hours and @ Full load = 47 hours. Includes Switch-Low Fuel
Level, Subbase and Switch-Annunciator, Liquid In Rupture Basin.
· 5 Year Comprehensive Warranty of Genset. Extends 1st year through 5 full years.
After 1st year, coolant heater not covered.