Diesel Generator Set
Cummins® Power Systems Industrial
50KW standby rated

Cummins brand power generation systems are the result of integrated design and manufacturing intended to satisfy your requirements for rated performance and reliable and efficient operation.  For either standby or prime power,

Extreme weather, construction activities, and countless other unforeseen power complications can suddenly interrupt the electrical service you depend on to continue your operations and activities.  You can have complete peace of mind, knowing that during a power outage your Cummins Standby System will activate to provide the power necessary to run vital systems.

Fully automatic, the system detects an interruption of electrical service and engages to power your essential systems.  When utility power is restored, the standby system shuts down, automatically resetting itself.  The entire power transfer cycle is fully automatic -- it is not necessary to be present for this system to work!

 

Cummins Diesel Generator Sets

Cummins series water-cooled diesel-fueled generator sets offer the traditional rugged durability and reliability in applications as diverse as standby power for nursing homes or wireless services and prime power for small, unattended remote stations or large applications.  User-friendly operation and maintenance features include:

* Weather-protective housings and coolant heaters to shield the genset
   from extreme ambient conditions.

* Space-saving options, such as in-skid fuel tanks

* Mulit-level controls for automatic, local, or remote start capabilities

* Complete options and accessories

If your requirements differ from those described here, click to request a custom quote.

 

Cummins Features

Compare these features with those offered on competitor's models.   Only more about the Cummins brand Cummins

* Single-source design, manufacturing and testing of all set components and
   accessories by Corporation.

* Most accept 100% of nameplate kW rating in one step, in compliance with
   NFPA 110, Paragraph 5-13.2.6.

* Shunt exitation system provides quick recovery from transient speed dips.

* Designed with a complete line of factory options and accessories for standby
   and mobile power.

* Water-cooled diesel engine is mechanically or electronically governed and
   has direct injection combustion.

* Most have brushless, rotating field YD AC alternator that provides broad range
   reconnectible output.  Single phase 4-lead alternator is standard with 12-lead
   optional.

* Control Panel: vibration isolated start/stop control with various shutdowns.

* Electronic voltage regulator provides precise regulation,
   underfrequency compensation, and fast recovery from transient speed dips.

* High ambient radiator cooling system.

* Skid base provides integral vibration isolation and supports the alternator and engine.
   Battery rack and cooling system mount to the skid base.  Skid bases are standard
   on water-cooled models.

 

Standard Bill of Material

50DGHE Cummins Genset-Diesel Powered,60Hz,50kW or 50,000 watts, 209 amps @ 240v.
A331-2 Duty Rating-Standby Power
L090-2 LISTING-UL2200
L060-2 Certification-EPA,Tier1
HOUSING Weather Protective with Critical Muffler and E-Coat finish. The E-Coat paint
       system makes for a high quality finish that protects against fading, corrosion,
       scratches, etc. 79.3 dba @ 23 feet. The Critical muffler is mounted inside
       enclosure. 
R104-2 Voltage-120/240, Single Phase
B268-2 Alternator-60hz,12 Ld,Broad Rng,Full 1ph Outp,105c - Largest alternator with
       lowest temp rise delivers the maximum amount of motor starting kva with the least
       amount of harmonics distortion from no load to full load, critical for sensitive
       electronic loads.
H643-2 SET CONTROL-Power Command Control 2100 - Very sophisticated commercial
       microprocessor control. Stores tons of information on the genset's performance and
       easily obtained at control panel. 
B240-2 Exciter/Regulator-Torque Match
A356-2 Engine Governor-Mechanical, 5% Droop
H536-2 Display Language-English
KM65-2 CircuitBreakerMtg-Single Brkr,LeftOfGenEnd
KB22-2 Circuit Breaker-225a,2pole,240v,Thermo-Magnetic,Ul
F179-2 Skidbase-Housing Ready
E082-2 Engine Cooling-Radiator, 50c Ambient
H389-2 Shutdown-Low Coolant Level - Protects engine from running with low coolant. 
E089-2 Extension-Engine Coolant Drain - Makes for quicker, easier service intervals.
H036-2 Coolant Heater-120 Volt Ac, Single Phase - AC engine heater maintains a warm
       temperature on the block that protects against wear and tear caused by cold
       weather engine starts.
L028-2 Genset Warranty-1 Year - Covers travel time, mileage, parts and labor for a period
       of one year following start-up services. 
A322-2 Packing-Skid, Poly Bag
F065-2 Rack-Battery
H268-2 Extension-Oil Drain - Makes for easier, quicker service intervals.

 

Options (order using drop down menus below)

· Upgrade to Stage 1 Sound Attenuated Enclosure. Decreases dba level from 79 to 70dba.
· Upgrade to Stage 2 Sound Attenuated Enclosure. Decreases dba level from 79 to 64.5.
· Electronic Governor- To replace the mechanical governor. Maintains the tightest
  frequency and voltage regulation from no load to full load. +/- ½ %. 
· 5 Year Comprehensive Warranty on Genset: Add $545. Extends the 1 year warranty through
  5 full years. Following the 1st year, the coolant heater is not covered.

 

Remember when selecting a diesel generator avoid extreme oversizing.  For proper performance you need to be able to achieve more than 30% of full load rating on a regular basis.  Otherwise you risk wet-stack problems and other issues.

 

Customers who purchased this product also ordered:
(click underlined words to see product pages)
Automatic transfer switch ATC3C2-200, ATC3C2-320, ATC3C2-400, ZTX20RM4ZTX30RM4, ZTX40RM4, RST200/176, OTEC400 (for 400 amp service you can use (2) 200A or (1) 400A switch)

 

Are YOU ready for the next power outage?

 1 Videos
 2 Outage Archives
 3 Utility Industry
 4 Why You Need Backup
 5 Personal Stories
 6 NoOutage Configurations
 7 Safety
 8 Sizing for Your Needs
 9 Voltage Drop Calculator
10 Test Reports
11 Placing Order
12 Equipment Leasing
13 Books & Videos  
14 Financing
15 Frequently Asked
16 Future Technologies
17 Electricity Glossary
18 Help with Plug Types
19 Who We Are
20 Why Buy Here
21 Our Customers
22 Pick a Contractor
23 Privacy Promise
24 Safe Shopping Guarantee
25 Terms & Conditions
26 What's New
27 Contacting Us
28 Parts Lookup
29 Parts & Service
30 Made in USA
31 Links

We welcome your feedback or questions.  Click here to contact us.
See our Terms & Conditions before using information or ordering from this web site.
Copyright © 1999-2025 NoOutage.com LLC. A Virginia LLC. All rights reserved.