Page last updated Jul 9, 2011 @ 12:26am
80DSFAE
Diesel Generator Set
Cummins® Power Systems Industrial
80KW standby rated
Cummins brand power generation systems are the result of integrated design and manufacturing intended to satisfy your requirements for rated performance and reliable and efficient operation. For either standby or prime power,
Extreme weather, construction activities, and countless other unforeseen power complications can suddenly interrupt the electrical service you depend on to continue your operations and activities. You can have complete peace of mind, knowing that during a power outage your Cummins Standby System will activate to provide the power necessary to run vital systems.
Fully automatic, the system detects an interruption of electrical service and engages to power your essential systems. When utility power is restored, the standby system shuts down, automatically resetting itself. The entire power transfer cycle is fully automatic -- it is not necessary to be present for this system to work!
Cummins Diesel Generator Sets
Cummins series water-cooled diesel-fueled generator sets offer the traditional rugged durability and reliability in applications as diverse as standby power for nursing homes or wireless services and prime power for small, unattended remote stations or large applications. User-friendly operation and maintenance features include:
* Weather-protective housings and coolant heaters to shield the genset
from extreme ambient conditions.* Space-saving options, such as in-skid fuel tanks
* Mulit-level controls for automatic, local, or remote start capabilities
* Complete options and accessories
If your requirements differ from those described here, click to request a custom quote.
Cummins Features
Compare these features with those offered on competitor's models. Only more about the Cummins brand Cummins
* Single-source design, manufacturing and testing of all set components and
accessories by Corporation.* Most accept 100% of nameplate kW rating in one step, in compliance with
NFPA 110, Paragraph 5-13.2.6.* Shunt exitation system provides quick recovery from transient speed dips.
* Designed with a complete line of factory options and accessories for standby
and mobile power.* Water-cooled diesel engine is mechanically or electronically governed and
has direct injection combustion.* Most have brushless, rotating field YD AC alternator that provides broad range
reconnectible output. Single phase 4-lead alternator is standard with 12-lead
optional.* Control Panel: vibration isolated start/stop control with various shutdowns.
* Electronic voltage regulator provides precise regulation,
underfrequency compensation, and fast recovery from transient speed dips.* High ambient radiator cooling system.
* Skid base provides integral vibration isolation and supports the alternator and engine.
Battery rack and cooling system mount to the skid base. Skid bases are standard
on water-cooled models.
Standard Bill of Material
80DSFAE Genset-Diesel,60Hz,80kW
A331-2 Duty Rating-Standby Power
L090-2 LISTING-UL2200
L097-2 Emissions-Tier3 levels
F173-2 Enclosure- Weather Protective Enclosure with internally mounted critical muffler
87.3dbA @ 23' and full load.
R104-2 Voltage-120/240, Single Phase
B268-2 Alternator-60hz, 4 Load, Full 1ph Output,125C
H643-2 SET CONTROL-PCC 2100
B184-2 Exciter/Regulator- Torque Matched
A366-2 Engine Governor- Mechanical
H536-2 Display Language-English
KM65-2 CircuitBreakerMtg-Single Brkr,LeftOfGenEnd
KB26-2 Circuit Breaker-400a,2pole,240v,Thermo-Magnetic,Ul
C168-2 Fuel Tank-dual wall subbase 146gal, 38hrs @ half load, 21hrs @ full load
C157-2 Switch-low fuel level, subbase
C169-2 Switch-annunciator, liquid in rupture basin
F179-2 Skidbase-Housing Ready
E082-2 Engine Cooling-Radiator, 50c Ambient
H389-2 Shutdown-Low Coolant Level
E089-2 Extension-Engine Coolant Drain
H036-2 Coolant Heater-120 Volt Ac, Single Phase
L028-2 Genset Warranty-1 Year Base
A322-2 Packing-Skid, Poly Bag
F065-2 Rack-Battery
H268-2 Extension-Oil Drain
Options (order using drop down menus below)
· Stage 1 Sound Attenuated Enclosure. Decrease sound level to 81.9dba.
· Stage 2 Sound Attenuated Enclosure. Decrease sound level to 71.8dba.
· 12 lead Alternator - This larger alternator end allows for maximum motor starting kva
and the least amount of harmonics distortion from no load to full load. The lower the
temp rise, the greater the decrease of harmonics distortion. Also, if the set should
ever have to be relocated a 12 lead alternator can be reconnected to any 3 phase
voltage, so resale value would be greater.
· Electronic Governor - Maintains tight frequency and voltage regulation to +/- ½ %
as opposed to mechanical governors, which produce a wider range.
Remember when selecting a diesel generator avoid extreme oversizing. For proper performance you need to be able to achieve more than 30% of full load rating on a regular basis. Otherwise you risk wet-stack problems and other issues.
Customers who purchased this product also ordered:
(click underlined words to see product pages)
Automatic transfer switch ATC3C2-200, ATC3C2-320, ATC3C2-400, ZTX20RM4, ZTX30RM4, ZTX40RM4, RST200/176, OTEC400 (for 400 amp service you can use (2) 200A or (1) 400A switch).
Click here for complete listing of automatic transfer switches.
Item Number: 80DSFAE
Price: $22,794
Shipping Weight: 3000 lbs.
This item normally ships in approximately 6 weeks or less.