Air Cooled Load Banks

These are resistive load banks suitable for testing generator sets and UPS systems.
Durable construction for repeated use such as in production line testing.
The lighter-weight units are also perfect for field service personnel.
Send us e-mail if you need DC load banks or larger models.

table-arrow.gif (695 bytes)

Description

Load Steps (kW)

Price
$ US

D22867 Load Bank - 10kW, 120VAC, 1 phase 0.25, 0.25, 0.5, 1, 2, 3, 3 discontinued
D23572 Load Bank - 10kW, 120/240VAC, 1 phase 1, 2, 2, 2, 3 discontinued
D27985 Load Bank - 20kW, 120/240VAC, 1 phase 1, 1, 2, 2, 2, 3, 3 discontinued
D27987 Load Bank - 25kW, 240/480VAC, 3 phase 1, 2, 4, 8, 10 discontinued
LIBERTY Load Bank - four models:
     25kW 120/240Vac 1ph
     55kW 120/240Vac 3ph
     65kW 208Vac 3ph
     75kW 240Vac 1ph

0.5, 0.5, 1, 2, 3, 3, 3, 3, 3, 3, 3
5, 10, 20, 20
5, 10, 10, 20, 20
1, 2, 2, 5, 10, 15, 20, 20
$6,817
FREEDOM Load Bank - two models rated 60Hz and 50Hz
     100kW max 480V 3ph 60Hz
      86kW max 415V 3ph 50Hz

5, 10, 10, 25, 50
5.4, 10.8, 10.8, 26.9, 32.3
$8,558
PATRIOT Load Bank - four models:
     500kW 240/480Vac 3ph
     700kW 240/480Vac 3ph

5kW or 50kW step resolution
5kW or 50kW step resolution
$20,287

 

Water Cooled Load Banks

These are resistive load banks suitable for testing generator sets and UPS systems.  The 
X-series load banks require a clean water source with low mineral content of 7.5 gpm
for each 150kW load unit.  Salt water and high mineral content water will alter the
resistance since elements are in electrical contact with the cooling water.  Water is
usually provided using a garden hose for single load units or a fire hose for multiple units.
A cooling tower source can also be used as long as there is no sediment in the water
and adequate flow is provided.
The N-series load banks use resistive elements that are electrically insulated from the
cooling water so water quality will not affect load values.
As compared with air cooled load banks of similar ratings, these water cooled
units are smaller in size, lighter weight and available with shorter factory lead times.
Resistor elements can easily be changed in the field for different ratings.

table-arrow.gif (695 bytes)

Description

Use With

Price
$ US

N-WCLB-1 Load Bank - complete with resistor elements, 3 load steps, metering, single phase, 60kW max at 240V, other voltages available   $2,729
N-WCLB-3 Load Bank - complete with resistor elements, 3 load steps, metering, 3 phase NEW   $2,599
X100 Basic Load Bank Tank - 150kW max, 600VAC max, 3-phase (order resistor elements separately) all resistor elements below, DISTRIB-8, DISTRIB-12 $2,644
X600A High Capacity Load Bank - 600kW max, 380VAC to 600VAC, 3-phase, with 4 switching contactors rated 250A (order resistor elements separately) all resistor elements below except 208V and lower, HOSE1.5 $21,159
X600B High Capacity Load Bank - 600kW max, 208VAC max, 3-phase, with 4 switching contactors rated 350A (order resistor elements separately) resistor elements rated 208V and lower, HOSE1.5 $24,000
RES208 X Resistor Elements - 208VAC, 3-phase X100, X600B $499
RES380 X Resistor Elements - 380VAC, 3-phase X100, X600A $499
RES415 X Resistor Elements - 415VAC, 3-phase $499
RES480 X Resistor Elements - 480VAC, 3-phase $499
RES600 X Resistor Elements - 600VAC, 3-phase $399
RES-CUSTOM X Resistor Elements - 3-phase, custom voltage & kW   $599
DISTRIB-8 Water Distribution Assembly - inlet for up to eight X-100 load banks, 1.5" connection for inlet hose X100, HOSE1.5 $624
DISTRIB-12 Water Distribution Assembly - inlet for up to twelve X-100 load banks, 2.5" connection for inlet hose X100, HOSE2.5 $755
HOSE1.5 Fire Hose - 1.5" diameter, 50 ft long DISTRIB-8, X600A, X600B $466
HOSE2.5 Fire Hose - 2.5" diameter, 50 ft long DISTRIB-12 $727

 

NOTES:
Larger resistive load banks and reactive load banks are available along with units suitable for DC testing.  Go to our Large Load Bank page for details.

 

Are YOU ready for the next power outage?

 1 Video Introduction
 2 Outage Archives
 3 Utility Industry
 4 Why You Need Backup
 5 Personal Stories
 6 NoOutage Configurations
 7 Safety
 8 Sizing for Your Needs
 9 Voltage Drop Calculator
10 Test Reports
11 Placing Order
12 Equipment Leasing
13 Books & Videos  
14 Financing
15 Frequently Asked
16 Future Technologies
17 Electricity Glossary
18 Help with Plug Types
19 Who We Are
20 Why Buy Here
21 Our Customers
22 Pick a Contractor
23 Privacy Promise
24 Safe Shopping Guarantee
25 Terms & Conditions
26 What's New
27 Contacting Us
28 Generator Shortage
29 Parts & Service
30 Made in USA
31 Links

We welcome your feedback or questions.  Click here to contact us.
See our Terms & Conditions before using information or ordering from this web site.
Copyright 1999-2012 NoOutage.com LLC.  All rights reserved.