Description
Tripp Lite's Omni Smart 1400 Hospital-Grade UPS System provides intelligent,
line-interactive battery backup for personal computers, network workstations and servers.
1400 VA of battery backup allows you to work through short blackouts or safely shutdown
during longer ones. The unit has 6 hospital-grade outlets, diagnostic LEDs, and a built-in
serial port that works with PowerAlert Software to provide automatic unattended shutdown.
Key Buying Points
Meets UL 544 requirements for medical and dental equipment - leakage current <100
micro amps
1400 VA output power rating (940 watts)
Up to 75 minutes typical backup time
6 protected hospital-grade, outlets; 6-ft. cord with hospital-grade plug
DB9 serial port for network interface; SNMP compatible
Line-interactive with 4 levels of automatic voltage regulation (AVR)
Complete surge protection and EMI/RFI noise filtering
PowerAlert unattended shutdown software and 6-ft. network cable included
Year 2000 compliant
4 diagnostic LEDs indicate line ok, on battery, voltage correction & battery
low/replace
Area Applications
Laboratories, nurses' stations, medical/dental offices, and stationary/mobile medical
record systems.
Typical Applications
Network workstations, small office servers, hubs, routers, personal computers, and
more.
Package Includes
Omni Smart 1400 Hospital-Grade UPS System
PowerAlert Software and 6-ft. network cable
Instruction manual
Specifications
UPS type Line Interactive UPS protects connected equipment from blackouts,
brownouts, overvoltages, surges and line noise. Features low leakage current (within UL544
specifications) and hospital grade plug and receptacles. Includes LAN port, bundled
software, 'surge only' outlets and modem line surge suppression.
Input/output voltage 120
Input/output frequency (Hz) 60
Ouput VA 1400
Output watts 940
On-line waveform Pure Sine
On battery waveform PWM Sinusoidal
Voltage regulation Line interactive system corrects voltage to nominal levels, boosting
input between 86 to 112 volts and reducing input between 127 and 145 volts. Output voltage
in battery mode is regulated to 120 volts +/- 5%.
Full load runtime (min.) 8
1/2 load runtime (min.) 24
Typical runtime (PC w/15" mon.) up to 75 min.
External battery compatible n/a
Recharge rate to 90% (hours) 2-4
Transfer time (milliseconds.) 2-4
Suppression joule rating 240
Maximum surge current (amps) 18,000
Suppression response time 5 nanoseconds (Protection between H-N only to meet Hospital
Grade leakage requirements).
EMI/RFI noise reduction Greater than 80 dB @ 1 MHz
High volt switch to battery 145
Low volt switch to battery 86
UPS supported outlet type / qty. 6 NEMA 5-15R
Cord length 6 feet
Dimensions HxWxD (inches) 10 x 6.5 x 14
Shipping weight (lb..) 44
Fax/modem surge protection Set of RJ11 jacks protect two phone lines simultaneously
Network interface port Built in DB9 standard communications port for use with PowerAlert
software and cabling.
Software & cable included Includes cable and CD-ROM with PowerAlert Plus software.
Product warranty (yr.) 2
Connected equipment warranty n/a
Battery access Battery Door
Controls, indicators and additional features On/off and Self test/alarm silence switches,
LEDs indicate on-line,on-battery, voltage correction, and battery low/replace, audible
alarms. Hospital Grade plug and outlets with less than 100 microamps of leakage.