Page last updated Jul 27, 2023 @ 10:20am
Hydroelectric Generators
- Hydroelectric Turbine Generators
Aquair submersible, Harris Pelton, Turgo low head
- Hydroelectric Accessories
props, pelton wheels, nozzles, gauges
- Hydroelectric Power Information
general intro, How much can you generate?, pipelines, nozzle selection, measuring head & flowA hydroelectric system requires more than just the turbine and generator.
For a complete system with a dc source you will also need a diversion load controller, diversion load, dc-to-ac inverter, switchgear, battery bank, wire and cable, water intake screen, piping and valves, weather protected powerhouse, etc. We can quote most of these items. Total system cost is several times the cost of the turbine alone.
If you are comparing to a PV solar system keep in mind that the Wattage of a hydroelectric turbine generates more than five times the electricity as a similar Wattage solar system because hydro runs 24 hours per day.
In the USA access to water and the use, control and diversion of water flows is subject to federal and state regulation. This is true regardless of whether or not the stream is on private property. Be sure to read Regulation of Hydro Projects on our Hydroelectric Information page before ordering.
For detailed descriptions and buttons to add items to your shopping cart, click on item number in first column of tables below. For detailed online ordering steps, click here. We are continually adding new products and updating prices, so check back soon.
Hydroelectric Turbine Generators
When comparing the cost per watt for these systems to solar or wind, keep in mind that you may get far more total energy out since they can operate 24 hours per day as long as water is available. Maximum electrical output may not be achieved unless proper pressure and flow are available. For more on this see information page.
Micro hydroelectric generators are not UL Listed. If your installation will be inspected make sure this is acceptable before ordering.
Brand | Water Supply |
Max. Electrical Output |
¢/kWH see footnote |
Price $ US |
|
DCPAT-20 | NoOutage | 81ft
35psi 7gpm 74ft 32psi 11gpm 46ft 20psi 10gpm |
40W 1.6A @
24Vdc 28W 1.9A @ 12Vdc 17W 1.2A @ 12Vdc |
discontinued | |
Q01-1012 Q01-1024 Q01-1048 |
Ampair | for towing with a sail boat | Wind/Water Hybrid 100W, 40mph wind, 12 or 24 or 48VDC 80W, 8mph water, 12 or 24 or 48VDC |
13¢ | not currently
available |
AQUAIR-UW | Ampair | 6-9 mph velocity typical | 60-100 watts, 12, 24 or 48VDC |
14¢ | not currently available |
LV400/750 | HI Power (P.M. alternator) |
20-100 ft (10-40
psi) 5-70 gpm per nozzle |
12, 24, 48,
120VDC 800W max |
> 2.1¢ | starting at $1,549 |
LV800/1500 | HI Power (P.M. alternator) |
100-400 ft
(40-170 psi), 5-100 gpm |
12, 24, 48,
120VDC 1500W max |
> 1.1¢ | starting at $1,549 |
HV1200 HV2000 HV4000 |
HI Power (induction gen) |
100-200 ft (40-90
psi), 5-250 gpm |
12, 24, 48VDC 1200, 2000, 4000W max |
> 1.7¢ | starting at $3,640 |
HV2INTERTIE HV4INTERTIE HV5INTERTIE |
HI Power (induction gen) |
100-200 ft (40-90
psi), 5-250 gpm |
240VAC 2000, 4000, 5000W max |
> 2.2¢ | starting at $5,899 |
SCOTT | Scott Hydroelectric | 10-35 ft (4-15
psi), 520 gpm |
130-200 Vac for
transmission line to rectifier for dc output 1500W max |
> x.x¢ | discontinued |
LVPM |
Lo Power Eng'g (P.M. alternator) |
40-600 ft, 4-250 gpm |
12, 24, 48, 96VDC 1500W max |
> 2¢ | starting at $1,461 |
HARRIS | Harris Hydro | 20-600 ft, 4-250 gpm |
750W @ 12VDC 1500W @ 24VDC 2500W @ 48VDC |
> 2¢ | starting at $1,911 |
NOTE: ¢/kWH based on purchase cost of hydroelectric turbine spread over 10 years of kWH generated at rated power output. Figures do not include costs of piping, balance of system components, installation or maintenance. Credits for state and federal incentives not included. Performance and ¢/kWH will vary considerably depending on actual head, flow and any out of service time. Formula: ¢/hWH = 1.14 x $price ÷ Watts
Description | Use With | Price $ US |
|
HARRIS-RUNR | Runner - Harris bronze or stainless steel Pelton wheel, 4 inch | HARRIS, LV750, LV1500 | $383 |
HARRIS-NOZ | Nozzle - Harris turbine, also fits HI Power LV series | $14 | |
HARRIS-PM | Upgrade Kit - upgrades old Harris Ford alternator to higher efficiency permanent magnet alternator | starts at $599 |
|
APRS8420 APRS8421 HL-100 HL-75 |
Diversion Load - air heating dummy load for use with load controllers and micro hydroelectric and wind generators, 14V to 120V AC or DC max | $270 | |
DLOAD-WTR | Diversion Load - water heating dummy load for use with load controllers and micro hydroelectric and wind generators, 14V, 28V or 56V AC or DC max | $131 | |
PRESSGAUGE | Pressure Gauge - 30, 60, 100, 160, 200 or 300 psi | any hydro system | $20 |
MNEMS4024PAECL150 MNEMS4024PAECL200 MNEMS4448PAECL150 MNEMS4448PAECL200 |
Pre-wired ePanel - includes Magnum inverter/charger, Midnite Classic Controller, accessories, factory wired and tested | any microhydro system, optional solar input |
starts at $4,946 |
Are YOU ready for the next power outage?
We welcome your feedback or questions. Click here to contact us.
See our Terms & Conditions before using information or
ordering from this web site.
Copyright © 1999-2024 NoOutage.com LLC. All rights reserved.