HOME POWER® Tri-Fuel Portable Generators by Winco keep you out of the dark. The unit operates on gasoline, LP gas or natural gas, and converting from one fuel source to another can be accomplished quickly and easily. HOME POWER® Tri-Fuel generators are powered by premium-quality, long life engines with low oil protection. The powerful, high-quality generator features inherent voltage regulation and protection for optimum reliability and safety. 120/240 volt AC single-phase, 60 cycle electric power is available through the receptacles provided in the output panel. The sturdy cradle design provides full protection and makes handling and storage easy.
Features:
* 4-wheel kit included
Engine
* special carburetor and secondary gas regulator allows engine to operate on gasoline, LP or natural gas fuels
* low oil protection
* standard electric start with battery rack and cables (battery not included due to shipping regulations)
* maintenance-free electronic ignition system
* dual element air filter reduces maintenance
Generator
* proven, dependable, efficient design
* inherent voltage regulation for stable output and optimum reliability
* 100% copper windings with NEMA Class F insulation
* capacitor excitation for brushless operation
Output Panel
* 120V and 240V receptacles
* 4-prong 120/240V receptacles suitable for connection to manual transfer switches
* circuit breaker protection
Specifications
Engine Make | Honda |
Engine Type | GX620 OHV, 620cc |
Engine Rating | 20 hp |
Engine Speed | 3600 rpm at 60Hz |
AC Output Voltage | 120/240VAC, 60 Hz |
AC Output Power | 10,800W continuous/12,000W surge
(gasoline) 9,720W continuous/10,800W surge (propane) 8,640W continuous/ 9,600W surge (natural gas) |
Output Receptacles | (4) 120V 20A GFCI duplex NEMA 5-20R (1) 240V 30A twistlock NEMA L14-30R (1) 240V 60A straight blade NEMA 1460R |
AC Motor starting ability | 6 hp Code G capacitor start motor |
Fuel Tank Capacity | 15 gal extended run |
Fuel Consumption | 1.67 gal/hr gasoline 3.5 gal/hr propane (est.) 260 cu.ft./hour natural gas (est.) |
Starting System | electric (battery not included) |
Low oil protection | yes |
Dimensions (L x W x H) inches | 39.5 x 26 x 26 |
Manufacturer's warranty | 1 year generator, 2 yrs engine |
Changing Fuel Types (this is a summary, see manual for complete details)
From Gasoline to LP or NG
* with the engine running turn off the gasoline fuel valve
* run the engine until it runs out of fuel
* remove the pipe plug from the demand regulator (on the engine)
* install locally approved flexible fuel line
* connect the LP or NG vapor fuel line
* turn on the vapor fuel - must be 7-11 inches of water column pressure
* start the engine
* apply the electrical load to the generator
* adjust the fuel mixture valve to smooth the engine out
From LP/NG to gasoline
* with the engine running turn off the LP/NG fuel supply
* run the engine until it runs out of fuel
* remove the flexible fuel line from the demand regulator
* reinstall the pipe plug in the regulator
* check to be sure the gasoline fuel valve is off
* fill the gasoline fuel tank
* turn on the gasoline fuel valve
* start the engine
* adjust the load jet on the carburetor as required to smooth the engine out
Optional Accessories
- single point lifting bar
- safety shutoff vapor fuel solenoid, 12Vdc operated, recommended for long
unattended operation