| System AC Line Input Voltage |
120VAC nominal
(77-152VAC limits) |
| System AC Line Input Frequency |
60Hz +4Hz |
| AC Line Circuit Capacity |
30 amps 120VAC minimum |
| Portable Generator Size (optional) |
5000 Watts rated w/ 30 amp
120VAC receptacle and voltage regulator (recommended) See NOTE 1 |
| System DC Voltage
& Battery Bank - see NOTE 3 |
120 VDC nominal
(10) 12V 5Ah internal batteries
(20) 12V batteries per external module |
| Inverter Power Output Rating |
2400VA / 2250 Watts continuous
2650VA / 2500 Watts surge for 2 minutes
>2700VA / >2600 Watts for 0.2 seconds
see NOTE 2 |
| System output voltage (on inverter) |
120VAC +5%
pure sine wave |
| Automatic Transfer Time |
4 milliseconds
typical |
| System efficiency |
95% |
Approximate Battery Run-Time
See NOTE 4 |
internal battery only |
500VA/450 watts
average
1000VA/900 watts average |
0.8 hours
0.4 hours |
| 1 optional external battery
module |
500VA/450 watts
average
1000VA/900 watts average |
3.0 hours
1.52 hours |
| 2 optional external battery
modules |
500VA/450 watts
average
1000VA/900 watts average |
5.2 hours
2.6 hours |
| 3 optional external battery
modules |
500VA/450 watts
average
1000VA/900 watts average |
7.4 hours
3.7 hours |
| 4 optional external battery
modules |
500VA/450 watts
average
1000VA/900 watts average |
9.5 hours
4.8 hours |
| Battery Charger Rating |
6-10A at 120Vdc
nominal (approx 1000 watts) |
| Approximate Battery
Recharge Time |
Internal battery: 3
hours to 90% usable capacity
External Batteries: no more than 15X discharge time |
| Indicators
(red/green/flash/audible alarm) |
-
Power On LED
- Site wiring fault LED
- Battery Service LED
- On Battery LED
- General Alarm LED
- Load Level LEDs (5) |
Communication
Ports
(work with included LanSafe software) |
- RS232 DB9 Communication port with cable
(factory installed in X-slot) |
Surge Suppression
(active in both normal and bypass modes) |
ANSI
C62.41 Category B
IEC 61000-4-5 Level 3, Criteria B |
| Audible Noise (UPS
module) |
<45dbA
normal mode with typical load
<50dbA in battery mode |
| Environmental
Ratings |
0C to
40C operating (25C optimal for batteries)
-25C to +55C transient
5% to 95% relative humidity, non-condensing
2,000 meters elevation above sea level max
System will function at reduced performance outside the operating range. |
Dimensions &
Weights
(all are 2U 3.5" H x 17.5" W) |
- UPS
module 24.5" D, 92 lbs
- optional battery modules 24.5" D, 121 lbs |
| Warranty by
Manufacturer |
- 2
years parts & labor
- 10 years pro-rated |
| Certifications |
UL
Listed, cUL, CE |
NOTES:
1 - Oversized generators with automatic voltage regulators work
best.
2 - This system will start most home refrigerator and freezer compressor
motors.
3 - Under normal conditions batteries should last at least 3-5
years. Replacement batteries are available and can be installed by
user.
4 - Battery run-time is not linear. At half the stated electrical
load the run-time will be MORE than double the original value. |