Page last updated Oct 20, 2021 @ 10:12pm
HUPS51252K UPS Systems
DISCONTINUED AND REPLACED
WITH HUPS-NXRT3
![]() |
![]() |
| front view with
2 optional battery modules |
system diagram |
|
Click thumbnail image above to enlarge. (Tower mounting configuration shown.) |
|
House UPS System
2200VA/1920 watt, 120VAC
Our House UPS systems fill a market niche between portable generators and automatic standby generators. Most power outages last less than a couple hours and these systems easily provide backup AC power for that length of time. These systems are silent and fully automatic and transfer extremely fast when line power is lost. No more guessing how long an outage will last and whether it is worth the trouble to drag out that portable generator. For most outages which are short this system eliminates that trouble!
For details about how this system operates and its advantages click here.
What is included in the NoOutage.com House UPS System?
We provide everything you need to install an operational system except for one circuit breaker that must be installed in your load center breaker panel and a connected wall outlet. If you want to be able to provide backup power for a long-term power outage you will also need a portable generator (not included). Make sure the generator has a high capacity 120V 30A NEMA 5-20R receptacle. System includes the following:
| * UPS Module * Transfer Switch - 4 circuit * battery charger (in UPS) |
* AC Input Cord - 25' with NEMA
5-20P Plug * AC Output Cord with NEMA L5-30C Connector * interconnecting battery jumper cables * gel cell maint-free lead acid batteries (in UPS) |
We do not provide the circuit breaker for your load center panel due to the many brands of panels. Purchase one locally that fits your panel. It should be rated 20 amps. Your installer will also need to wire this breaker to a 20A 120VAC NEMA 5-20R wall receptacle near the UPS.
System Specs
| System AC Line Input Voltage | 120VAC nominal (80-151VAC limits) | ||
| System AC Line Input Frequency | 60Hz (56.5-70.0Hz) | ||
| AC Line Circuit Capacity | 20 amps 120VAC minimum | ||
| Portable Generator Size (optional) | 5000 Watts rated w/ 30 amp 120VAC receptacle and voltage regulator (recommended) See NOTE 1 | ||
| Inverter Power Output Rating | 2200VA /
1920 Watts continuous see NOTE 2 |
||
| System output voltage (on inverter) | 120VAC
(-10% to +6%) pure sine wave |
||
| Automatic Transfer Time | 4 milliseconds typical | ||
| System efficiency | >94% | ||
| Approximate Battery Run-Time See NOTE 4 |
internal battery only | 500 watts
average 1000 watts average |
0.8 hours 0.4 hours |
| 1 optional external battery module | 500watts
average 1000 watts average |
3.1 hours 1.3 hours |
|
| 2 optional external battery modules | 500 watts
average 1000 watts average |
5.2 hours 2.3 hours |
|
| 3 optional external battery modules | 500 watts
average 1000 watts average |
9.1
hours 4.0 hours |
|
| 4 optional external battery modules | 500 watts
average 1000 watts average |
12.1
hours 5.3 hours |
|
| Approximate Battery Recharge Time | Internal battery: 3
hours to 90% usable capacity External Batteries: no more than 15X discharge time |
||
| Indicators | 13 LED indicators | ||
| Communication Ports | USB & RS232 | ||
| Surge Suppression (active in both normal and bypass modes) |
yes | ||
| Audible Noise (UPS module) | 45dbA maximum | ||
| Environmental Ratings | 0C to
35C operating (25C optimal for batteries) 20% to 95% relative humidity, non-condensing 3,000 meters elevation above sea level without derating System will function at reduced performance outside the operating range. |
||
| Dimensions &
Weights (all are 2U 3.5" H x 17.5" W) |
- UPS
module 25" D, 75 lbs - optional battery modules 25" D, 92 lbs |
||
| Warranty by Manufacturer | 2 or 3 years | ||
| Certifications | UL Listed, cUL, CE |
||
| NOTES: 1 - Oversized generators with automatic voltage regulators work best. 2 - This system will start most home refrigerator and freezer compressor motors. 3 - Under normal conditions batteries should last at least 3-5 years. Replacement batteries are available and can be installed by user. 4 - Battery run-time is not linear. At half the stated electrical load the run-time will be MORE than double the original value. |
|||
Optional Features available at additional cost
The following optional features can be ordering using the drop-down menus at the bottom of this page. Click thumbnail images at right to enlarge.
External extended run-time battery module. Up to 4 maximum can be added to UPS system. Each module has short DC plug cord and connector on back to allow daisy-chaining together. X-Slot SNMP/Web Adaptor Card for management of UPS through web interface. UPS comes standard with software and serial cable but if you prefer remote control and monitoring through the web this card will do it. Fits in X-slot in rear. Includes built-in switch hub. X-slot Relay Interface Card provides dry contact interface between UPS and any external contact operated device. Individual form-C contacts provided for many UPS status conditions including utility failure, low battery, UPS alarm/Ok, or on bypass. Can be used to initiate start of standby generator or to perform other external control functions.
Are YOU ready for the next power outage?
We welcome your feedback or questions. Click here to contact us.