HUPS51253K UPS Systems

DISCONTINUED - SEE OTHER SYSTEMS HERE

hups51253k-front.jpg (13072 bytes) hups51253Kconn.jpg (39141 bytes)
front view with transformer module and 1 optional
battery module
system
diagram

Click thumbnail image above to enlarge.
(Tower mounting configuration shown.)

House UPS System
3000VA/2700 watt, 120/240VAC
(description and specs being revised)

 

Our House UPS systems fill a market niche between portable generators and automatic standby generators.  Most power outages last less than a couple hours and these systems easily provide backup AC power for that length of time.  These systems are silent and fully automatic and transfer extremely fast when line power is lost.  No more guessing how long an outage will last and whether it is worth the trouble to drag out that portable generator.  For most outages which are short this system eliminates that trouble!

For details about how this system operates and its advantages click here.

 

What is included in the NoOutage.com House UPS System?

We provide everything you need to install an operational system except for one circuit breaker that must be installed in your load center breaker panel and a connected wall outlet.  If you want to be able to provide backup power for a long-term power outage you will also need a portable generator (not included).  System includes the following:

* UPS Module 
* Output Transformer
* Maintenance bypass switch
* Transfer Switch - 6 circuit
* interconnecting AC jumper cables
* AC Input Cord - 25' with NEMA L1420P Plug
* AC Output Cord with NEMA
L1420C Connector
* interconnecting battery jumper cables
* gel cell maint-free lead acid batteries (in UPS)
* battery charger (in UPS)

We do not provide the circuit breaker for your load center panel due to the many brands of panels.  Purchase one locally that fits your panel.  It should be rated 30 amps.  Your installer will also need to wire this breaker to a 20A 120/240VAC NEMA L1420R wall receptacle near the UPS.  

 

What if I already have a generator transfer switch?

We can sell you this House UPS System without the transfer switch at a cost savings to you.  However, be sure you have the correct type of switch.  It MUST be a 120/240VAC multi-circuit transfer switch with inlet for cord on front similar to the Gen/Tran, Pro/Tran or Coleman models below.  These switches allow you to INDIVIDUALLY transfer household circuits one at a time to the generator.  Some switch and panel models (usually the type that have molded case circuit breakers) are not suitable because you have to transfer ALL circuits to the generator.  Click any of the underlined model numbers to see details.

Acceptable Acceptable Acceptable NOT Acceptable NOT Acceptable
Gen/Tran
20216
30216
302110
F20216
F30216
F302110
Pro/Tran
20216A
30216A
30508B
30310A
F20216B
F30216B
F30508B
F30310B
Coleman
PA0650080.01
PA0650081
Eaton
Cutler-Hammer
CH6EGEN
CH10EGEN

Square D
QO48M

Gen/Tran
200660
301060
501060

Panel/Link
TR...
TT...

 

System Specs
(being revised)

System AC Line Input Voltage 240VAC nominal (160-288VAC limits)
System AC Line Input Frequency 60Hz +4Hz
AC Line Circuit Capacity 20 amps 240VAC minimum
Portable Generator Size (optional) 5000 Watts rated w/ 20 amp 240VAC receptacle and voltage regulator (recommended)  See NOTE 1
Inverter Power Output Rating 3000VA / 2700 Watts continuous
see NOTE 2
System output voltage (on inverter) 120/240VAC +5%
pure sine wave
Automatic Transfer Time 4 milliseconds typical
System efficiency 95%
Approximate Battery Run-Time
See NOTE 4
internal battery only 500VA/450 watts average
1000VA/900 watts average
0.8 hours
0.4 hours
1 optional external battery module 500VA/450 watts average
1000VA/900 watts average
3.0 hours
1.52 hours
2 optional external battery modules 500VA/450 watts average
1000VA/900 watts average
5.2 hours
2.6 hours
3 optional external battery modules 500VA/450 watts average
1000VA/900 watts average
7.4 hours
3.7 hours
4 optional external battery modules 500VA/450 watts average
1000VA/900 watts average
9.5 hours
4.8 hours
Approximate Battery Recharge Time Internal battery: 3 hours to 90% usable capacity
External Batteries: no more than 15X discharge time
Indicators (red/green/flash/audible alarm) 13 LED indicators
Communication Ports  - USB, RS232
Surge Suppression
(active in both normal and bypass modes)
yes
Audible Noise (UPS module) 45dbA maximum
Environmental Ratings 0C to 35C operating (25C optimal for batteries)
20% to 95% relative humidity, non-condensing
3,000 meters elevation above sea level without derating
System will function at reduced performance outside the operating range.
Dimensions & Weights
(all are 2U 3.5" H x 17.5" W)
- UPS module 24.5" D, 92 lbs
- transformer module 23.9" D, 50 lbs
- optional battery modules 24.5" D, 121 lbs
Warranty by Manufacturer - 2 or 3 years
Certifications

UL Listed, cUL, CE

NOTES:
1 - Oversized generators with automatic voltage regulators work best.
2 - This system will start most home refrigerator and freezer compressor motors.
3 - Under normal conditions batteries should last at least 3-5 years.  Replacement batteries are available and can be installed by user.
4 - Battery run-time is not linear.  At half the stated electrical load the run-time will be MORE than double the original value.

 

Optional Features available at additional cost

The following optional features can be ordering using the drop-down menus at the bottom of this page.  Click thumbnail images at right to enlarge.

External extended run-time battery module.  Up to 4 maximum can be added to UPS system.  Each module has short DC plug cord and connector on back to allow daisy-chaining together.

hups5125ebm.jpg (8889 bytes)

X-Slot SNMP/Web Adaptor Card for management of UPS through web interface.  UPS comes standard with software and serial cable but if you prefer remote control and monitoring through the web this card will do it.  Fits in X-slot in rear.  Includes built-in switch hub.

hups5125webcard.jpg (21849 bytes)

X-slot Relay Interface Card provides dry contact interface between UPS and any external contact operated device.  Individual form-C contacts provided for many UPS status conditions including utility failure, low battery, UPS alarm/Ok, or on bypass.  Can be used to initiate start of standby generator or to perform other external control functions.

hups5125relaycard.jpg (7081 bytes)

 

 

 

Are YOU ready for the next power outage?

 1 Videos
 2 Outage Archives
 3 Utility Industry
 4 Why You Need Backup
 5 Personal Stories
 6 NoOutage Configurations
 7 Safety
 8 Sizing for Your Needs
 9 Voltage Drop Calculator
10 Test Reports
11 Placing Order
12 Equipment Leasing
13 Books & Videos  
14 Financing
15 Frequently Asked
16 Future Technologies
17 Electricity Glossary
18 Help with Plug Types
19 Who We Are
20 Why Buy Here
21 Our Customers
22 Pick a Contractor
23 Privacy Promise
24 Safe Shopping Guarantee
25 Terms & Conditions
26 What's New
27 Contacting Us
28 Parts Lookup
29 Parts & Service
30 Made in USA
31 Links